3. Insert the new battery:
4. Install the top cover (see "Removing and replacing consumable parts and Tier 1
5. Reconnect the external cables; then, reconnect the power cords and turn on the
6. Start the Setup utility and reset the configuration:
114
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide
a. Position the battery so that the positive (+) symbol is facing you.
b. Place the battery into its socket, and press the battery toward the housing
until it snaps into place.
CRUs" on page 105).
peripheral devices and the server.
Note: You must wait approximately 3 minutes after you connect the power
cord of the server to an electrical outlet before the power-control button
becomes active.
v Set the system date and time.
v Set the power-on password.
v Reconfigure the server.
See "Configuring the server" on page 202 for details.