Step
3.
Create an entry for
the interface in the
RMON statistics
table.
Creating an RMON history control entry
You can configure multiple history control entries for one interface, but you must make sure their entry
numbers and sampling intervals are different.
You can create a history control entry successfully even if the specified bucket size exceeds the available
history table size. RMON will set the bucket size as closely to the expected bucket size as possible.
To create an RMON history control entry:
Step
1.
Enter system view.
2.
Enter Ethernet
interface view.
3.
Create an entry for
the interface in the
RMON history
control table.
Configuring the RMON alarm function
When you configure the RMON alarm function, follow these guidelines:
•
To send notifications to the NMS when an alarm is triggered, configure the SNMP agent as
described in "Configuring SNMP" before configuring the RMON alarm function.
For a new event, alarm, or private alarm entry to be created:
•
The entry must not have the same set of parameters as an existing entry.
The maximum number of entries is not reached.
Table 8
shows the parameters to be compared for duplication and the entry limits.
Table 8 RMON configuration restrictions
Entry
Event
Command
rmon statistics entry-number
[ owner text ]
Command
system-view
interface interface-type
interface-number
rmon history entry-number buckets
number interval sampling-interval
[ owner text ]
Parameters to be compared
•
Event description (description string)
•
Event type (log, trap, logtrap, or none)
•
Community name (security-string)
175
Remarks
By default, the RMON statistics table does not
contain entries.
You can create one statistics entry for each
Ethernet interface, and a maximum of 100
statistics entries on the device. After the entry
limit is reached, you cannot add new entries.
Remarks
N/A
N/A
By default, the RMON history control
table does not contain entries.
You can create a maximum of 100 history
control entries.
Maximum number
of entries
60