Step
3.
Configure an event in
the policy.
Command
Configure a CLI event:
event cli { async [ skip ] | sync } mode
{ execute | help | tab } pattern
regular-exp
Configure a hotplug event (in
standalone mode):
event hotplug [ insert | remove ] slot
slot-number [ subslot subslot-number ]
Configure a hotplug event (in IRF mode):
event hotplug [ insert | remove ] chassis
chassis-number slot slot-number [ subslot
subslot-number ]
Configure an interface event:
event interface interface-type
interface-number monitor-obj
monitor-obj start-op start-op start-val
start-val restart-op restart-op restart-val
restart-val [ interval interval ]
Configure a process event (in
standalone mode):
event process { exception | restart |
shutdown | start } [ name process-name
[ instance instance-id ] ] [ slot
slot-number ]
Configure a process event (in IRF mode):
event process { exception | restart |
shutdown | start } [ name process-name
[ instance instance-id ] ] [ chassis
chassis-number [ slot slot-number ] ]
Configure an SNMP event:
event snmp oid oid monitor-obj { get |
next } start-op start-op start-val start-val
restart-op restart-op restart-val
restart-val [ interval interval ]
Configure an SNMP-Notification event:
event snmp-notification oid oid oid-val
oid-val op op [ drop ]
Configure a Syslog event:
event syslog priority level msg msg
occurs times period period
187
Remarks
By default, a monitor policy does
not contain an event.
You can configure only one event
in a monitor policy. If the monitor
policy already contains an event,
the new event overrides the old
event.