# On Device B, enable the synchronous mode and ESMC on GigabitEthernet 2/0/1.
<DeviceB> system-view
[DeviceB] interface gigabitethernet 2/0/1
[DeviceB-GigabitEthernet2/0/1] synchronous mode
[DeviceB-GigabitEthernet2/0/1] esmc enable
[DeviceB-GigabitEthernet2/0/1] quit

Verifying the configuration

# Verify that ESMC is enabled and QL information is exchanged correctly. The sample output on Device
A shows that the clock QLs of Device A and Device B are QL-PRC and QL-SEC, respectively. Device A
provides more precise timing than Device B.
[DeviceA] display esmc
Interface
Mode
ESMC status : Enable
Port status : Up
Duplex mode : Full
QL received : QL-SEC
QL sent
ESMC information packets received : 2195
ESMC information packets sent
ESMC event packets received
ESMC event packets sent
ESMC information rate
ESMC expiration
: GigabitEthernet2/0/1
: Synchronous
: QL-PRC
: 6034
: 1
: 1
: 1 packets/sec
: 5 seconds