Configuring the interval for sending Pdelay_Req messages

Step
1.
Enter system view.
2.
Enter Layer 3 Ethernet
interface view.
3.
Configure the interval for
sending Pdelay_Req
messages.

Configuring the interval for sending Sync messages

Step
1.
Enter system view.
2.
Enter Layer 3 Ethernet
interface view.
3.
Configure the interval for
sending Sync messages.
Configuring the minimum interval for sending Delay_Req
messages
Step
1.
Enter system view.
2.
Enter Layer 3 Ethernet
interface view.
3.
Configure the minimum
interval for sending
Delay_Req messages.
Command
system-view
interface interface-type
interface-number
ptp pdelay-req-interval value
Command
system-view
interface interface-type
interface-number
ptp syn-interval value
Command
system-view
interface interface-type
interface-number
ptp min-delayreq-interval value
125
Remarks
N/A
N/A
Optional.
The default is 1 (2
0
) second.
Remarks
N/A
N/A
By default:
The interval is 1 (2
0
) second if
the PTP standard is IEEE 1588
version 2.
The interval is 1/8 (2
if the PTP standard is IEEE
802.1AS.
Remarks
N/A
N/A
The default is 1 (2
0
) second.
When receiving a Sync or
Follow_Up message, an interface
can send Delay_Req messages
only when the minimum interval is
reached.