DIP Switch positions for the TME1 module
Figure 3-19
DIP Switch for the TME1 module
It is possible to configure the following settings by changing the positions of the Dip switches:
DIP Switch 1 (S1)
Allows you to delete the flash memory, or choose the baud rate.
Switch Procedure
1
FE
2
EST
2
EST
3
BR1
4
BR2
5
BR3
6
RES
7
RES
8
RES
Table 3-18
TME1 module, DIP Switch 1
Service Manual
Meaning
Flash memory off
Extended Autotest
(E1 CAS access)
Reserved for future applications (S2M access)
Baud rate
configuration
Possible settings
ON - Deletes Flash memory when the PABX is
turned on
OFF - System will work as usual (default).
ON - Activates autotest (E1 CAS access)
OFF - Skips autotest (default) (E1 CAS access).
(3) OFF, (4) OFF and (5) OFF: 9600 bps
(3) OFF, (4) OFF and (5) ON: 19200 bps
(3) OFF, (4) ON and (5) OFF: 38400 bps
(3) OFF, (4) ON and (5) ON: 57600 bps (default)
For future applications
Modules
Expansion modules (EB)
3-73