Table 3-39
Attribution of TFE-S contacts
Pin
X3 terminal
No.
1
AC
2
AC
3
Contact of the
electic
latch(TUE)
4
Contact of the
electric
latch (TUE)
Service Manual
X4 terminal
(a wire) -
Speaker (LS1)
(b wire) +
Speaker (LS2)
Contact of the
Microphone
bell (KLI)
(MIC+)
Contact of the
Microphone
bell (KLI)
(MIC-)
X5 terminal
X1 jumper
2 and 3 = Zn
1 and 2 = 600
ohm
Modules
Entrance telephone
X2 jumper
Ritto
2 and 3
Siedle
1 and 2
3-109