International Safety Standard; Environmental Conditions; Table 2-12 Environmental Conditions - Siemens HiPath 1100 Service Manual

Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

System Data
Technical standards and compliance
2.7.1

International Safety Standard

IEC 60950
2.7.2

Environmental conditions

Air Temperature (the
Relative humidity
Table 2-12
Environmental conditions
Servicing conditions (mechanical)
This system was essentially designed for installation at a fixed location.
Warning
!
Tthe avoid condensation when shipping the system in extremely low
temperatures, keep the equipment in its packaging until it reaches room
temperature. Proceed thereafter with the installation (acceptable temperature
range: 7.5•C (45.5•F)/30 min)
Do not expose the equipment to direct sunlight or place it near any heat sources
(to avoid a localized increase of temperature)
Make sure the installation area is dry. During system operation avoid any
conditions that may cause condensation.
Forced ventilation is not required.
Do not block the natural flow of air around the equipment.
Do not expose the equipment to the weather.
2-40
Operation
F
)
+41 to +86
5% to 85 %
Transportation
-13 to +158
95%
Storage
41 to +113
5% to 95%
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 1190Hipath 1150Hipath 1120