Configuring the system specifically for the client
Comments about the system's programming codes
Seizure priority by type of external line (194)
This setting specifies which type of external line will be seized when making an outgoing call.
External lines can be accessed using the access code "0" or the code specified for a group of lines.
If the PABX has digital and analog lines, you may specify which type of line will have priority.
External analog line seizure protocol (017)
This feature specifies the protocol to be used by the system for seizing an external analog line, based on the local carrier's
information.
This features is only available for Canada.
Caller ID for analog lines - CLIP (005)
Enabled by the local carrier, this service provides Caller ID over FSK and DTMF protocols on analog lines.
In the HiPath 1190 there is an upper limit of 16 lines configured with the CLIP DTMF option that causes limitations in the con-
ference feature depending on the number of lines being used by the CLIP DTMF at any given time. This is caused by the fact
that both the CLIP DTMF and the Conference use common resources in the system.
So, for example:
In a system with 16 CLIP DTMF lines there can be 2 conferences with 3 participants;
In a system with 8 CLIP DTMF lines there can be 1 conference with 8 participants or 2
conferences with 4 participants;
In a system with no CLIP DTMF lines there can be 2 conferences with 8 participants.
To free additional ports for use with the Conference feature without depending on the use of the CLIP DTMF , this function
should be disabled for certain lines.
When a country setting is specified, the appropriate protocol is automatically select-
ed.
External line call direction (155)
Specifies how to access external lines when receiving or making a call.
An external line can be:
1 = bidirectional
2 = Incoming unidirectional
3 = Outgoing unidirectional
Flash duration on an analog line (118)
Specifies the time during which the Flash signal remains active on the external analog line in relationship to the detection de-
faults set at the exchange.