Interface commands:
Command
Description
\nticket_start\n
This command will be sent by the user (Application) to the PABX, requesting
that the stored tickets start being sent.
\nticket_stop\n
This command will be sent by the user (Application) to the PABX, requesting
that the stored tickets stop being sent.
After receiving and accepting those commands, new tickets or tickets that are still
stored will not be transmitted to the PABX.
Interface answers:
Command
Description
\nend of tick-
This answer will be sent by the PABX to the Application interface when no
ets\n
stored tickets are left to be transmitted. This command can be used as an in-
dicator to end command "\nticket_start\n" when all stored tickets have been
sent.
\nprint_stopped\
This answer will be sent by the PABX to the Application interface after receiv-
n
ing command "\nticket_stop\n" to inform the user that the connection with
the application can be closed without losing the tickets.
To set up and use the Billing Application, please refer to the appropriate product
manual.
For Windows Hyper Terminal, the following setting is required:
Configure the CommSever for ADSL connection.
Select the "Serial Printing" checkbox on the HiPath 1100 Manager, under Advanced -
> System Settings
On the HyperTerminal, select TCP/IP Mode and enter the configuration number for an
ADSL module (the default is 10.0.0.1) and the port (9366) or SLIMC, SADSLIM, LIMC
or ADSLIM modules (the default is 192.168.254.253) and the port (9366).