Step
1.
Turn off the power supply.
2.
Remove the system's front cover.
3.
Remove the system's back cover.
4.
Move the module's latch as shown in figure 4-12.
5.
Insert the module into one of the slots shown in Table 4-2.
6.
Move the module's latch back to secure module.
7.
Connect the Main Distribution Frame cables as follows: For modules allocated to the
system's bottom slots (slots 1 to 10) use the bottom opening (see figure 4-10). For
modules allocated to the system's top slots (slots 11 to 20) route the cables through
the top anchors (See figure 4-11).
8.
Connect to the appropriate module Connectors (see "Expansion modules (EB)" on
page 3-58).
9.
Attach cables to anchors using plastic brackets.
10.
"Performing a visual inspection" on page 4-189.
11.
Reassemble the entire set.
12.
Turn on the power supply.
13.
Configure the required data (see "Operation" on page 7-278).
*
14.
Using Manager application go to: Advanced tab, > PBX Information tab, > Slot
Allocation tab;
Select the Clear All Slots checkbox;
Update the HiPath System;
Reset the HiPath System.
*