Installing a V.24 Interface

Introduction
To connect a computer/printer/modem to the HiPath 1100 using the RS 232 serial interface, you
must use the V.24 adapter cable (see "V.24 Adapter Cable" on page 3-113). If it is necessary
to use another serial cable as an extension to connect the computer/printer/modem to the
HiPath 1100, the maximum total length should not exceed 15 metres.
This interface allows you to use some applications developed specifically for configuring and
managing user features.
Connections
Step
1.
Attach the end of the interface interface cable with the Mini DIN Connector (male) to
the MB's serial Mini DIN Connector . Attach the other end to the printer or PC serial
port. When connecting to a PC, make sure that either the COM 1 or COM 2 port is
available.
2.
The following parameters can be configured when using a PC:
9600 / 14400 / 19200 (default) / 38400 / 56000 / 57600 / 115200 /128000 /
256000 baud
Fixed settings:
8 Bits
1 Stop Bit
No Parity
3.
When connecting to a printer, make sure the current time at the PABX is set
correctly.
Note
!
When using a LAN interface module, do not use the MB's serial Connector since the
serial connection is assigned to the HiPath 1100 module All functions of the serial
port are now executed over the LAN.