Siemens HiPath 1100 Service Manual page 240

Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Configuring the system specifically for the client
Comments about the system's programming codes
Incoming for VMI.
Connection type (133)
This setting determines whether the group of external lines that is connected to one of the HiPath 1100 systems is also inter-
connected to another C.O. or PABX.
Second external access code (134)
This setting determines the code to be sent by the Satellite PABX in accordance with the access code for external lines on the
Master PABX. This code is used for determining the availability of a dial tone on an external line.
Auto-seizure mode for an external line (036)
This feature dials an external call when the handset is lifted, without using an access code (e.g. 0). When this setting is selected
you must enter a code to dial internal calls or activate the Extension key.
Activating this feature may impact the programming of the Dialing Mode (Code 68),
assuming option 0 (Automatic ID) is selected. It is recommended that you reconfig-
ure the Dialing Mode (Pulse or Tone) for the extensions.
False tone (063)
This sends an external line dial tone even when there is no external line available (valid for MF/DP extensions only).
If LCR (configured via the
abled, the user will hear a False Tone regardless of what has been programmed.
Internal access code for Automatic seizure field (226)
This features specifies the code to be used for making internal calls when an extension is configured for Automatic Seizure of
an external line.
Access codes are configured according to the country. If no access code is specified, the feature will not work.
Country Code
Spain
99
Latvia
Lithuania
Australia
Greece
Italy
69
Portugal
6
Other
None
External line present (079)
This setting allows you to determine whether a given external line exists.
6-240
Emergency numbers
) or Emergency Numbers is en-
Service Manual