6.3.13

LAN interface modules

These provide a LAN Ethernet interface via their RJ45 connectors that allow direct PC connections to HiPath 1100 within the
network and if you have an ADSL modem available, they can share ADSL access, dispensing with the need for an external
ADSL modem or HUB.
The HiPath 1100 can interact via the LAN network with the applications used in your administration, such as: HiPath 1100 Man-
ager, Interaction Center Smart, billing applications, and so on.
Default Configuration of the LAN interface (013)
This code restores the default configuration of the LAN interface modules.
ADSL module
– Default IP of the module: 10.0.0.1
– Default Subnet Mask of the module: 255.255.255.0
SLIMC, SADSLIM, LIMC or ADSLIM modules
– Default IP of the modem: 192.168.254.254
– Default IP of the module: 192.168.254.253
– Default Subnet Mask of the module: 255.255.255.0
– Default gateway of the module: 192.168.254.254
6.3.14

Relay and sensor on the HiPath 1120

You can connect a Music module to the HiPath 1120 system. This module also provides a relay and a sensor for integrating
other devices such as an entrance telephone, a door opener, alarms, and so on.
Sensor:
When the state of a sensor changes (for example, when the sensor changes from an open contact to a closed contact), the
following functions can be executed:
Selection of a number in the Speed Dial Directory (Phonebook)
Activation of a relay
Dialing a number from the Speed Dial directory and activating a relay.
The activation logic based on the initial position of the sensor contacts as well as its resulting actions are programmable.
Relay:
If a sensor is programmed, the relay can be activated through that sensor. It can be activated either manually or automatically
after a specified time. When the relay is activated, the contacts close. When it is deactivated, the contacts open.
The name assigned to this position may have up to 15 characters.
Service Manual
Configuring the system specifically for the client
Comments about the system's programming codes
6-275