Configuring the system specifically for the client
Comments about the system's programming codes
Configuring the sensor function (170)
Allows you to select a function for the sensor:
Deactivating the sensor function (default)
Dial the number specified in "Number Dialed by Sensor Activation" (Code 052).
Activate the relay through the sensor
Detect DTMF code. When this setting is selected, the number that was called must
acknowledge or ignore an alarm call by sending an acknowledgement code ("#" DTMF
signal)
Sensor Activation Logic (174)
The basic position of the sensor can be set as follows: Contacts are closed and the sensor is activated when the contacts are
open or contacts are open and the sensor is activated when the contacts are closed.
Time between attempts for activating the sensor (050)
This setting specifies a timeout in minutes, after which a new attempt is made to call an internal or external number, if the
extension was busy.
MSN assignment for the sensor (051)
This setting specifies an MSN for the system, to be used for outgoing calls. With this MSN, the called party is able to identify
the origin of the call, for example an alarm call.
Number dialed by sensor activation (052)
This setting specifies the number to be automatically dialed when a specific sensor is activated. She number to be dialed when
the sensor is activated is stored in the System Speed Dial. When the number stored in the System Speed Dial is changed, this
field is updated, and vice-versa.
Number of attempts for activating the sensor (053)
This setting specifies the number of call attempts (between 1 and 100) for the number specified in "
by sensor activation
An attempt is made after every call that was not answered (busy signal), or when the "Detect DTMF Code" option (Code 70,
Option 3) is enabled and no acknowledgment is received. When this occurs, the call is disconnected and a new attempt is
made.
Relay (175)
This setting specifies the operating mode for the relay:
"Switch" The relay can only be turned on from an extension by entering the proper feature
code (see "Miscellaneous Functions - Relay" in the User Manual).
"Monoflop": The relay is closed for a specified length of time. Alternatively, the relay can
also be opened before the set time by entering the proper feature code (see
"Miscellaneous Functions - Relay" in the User Manual).
6-276
Time between attempts for activating the sensor
" . (See also
Number dialed
).