If you use the Trendnet V.92 56K - TFM-560X or D-Link V.90 56K - DFM - 560EL
modem you will need to use the analog modem adapter cable (see "Adapter cable
for analog modem" on page 3-118) and configure/check of the start-up and reset
code of the modem connected to the switch using HiPath 1100 Manager.
If the modem is connected to the PC (remote modem), the modem cable should be
used and the initialization code set using CommServer.
This information can be obtained from the modem's instruction manual.
In the Reset field the default setting for these modems is as follows:
US-ROBOTICS: ATZH0
TrendNet: ATZH0
D-LINK: +++,,,ATHATZH0
In the Initialization field, the default setting for these modems is as follows:
US-ROBOTICS: AT&F0&B1F1S0=0
TrendNet: AT&F0&B1F1&D0S0=0.
D-LINK: AT&F0&D0S0=0
7.2.2.2
ISDN modem via S
The system can be administered remotely or locally through an ISDN interface.
For this option, only the HiPath 1100 applications are installed. After restarting the computer
(if Windows prompts you to restart the computer) configure the settings for the CommServer.