Siemens HiPath 1100 Service Manual page 273

Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

S
line operation mode (190)
0
This setting specifies the type of connection, either Point-to-Point, Point-to-Multipoint, or S
the local carrier's lines.
With the HiPath 1120, the S
cannot be programmed as an S
With other switches, the first port may also be configured as an S
Symmetric/Asymmetric Call (074)
This setting configures the system for symmetric or asymmetric calls.
Check with your local carrier to find out which operating mode should be configured for your system.
No ACK Setup for S
Check with your local carrier to find out which operating mode should be configured for your system.
Notify (076)
Check with your local carrier to find out which operating mode should be configured for your system.
Automatic Keypad (077)
Your local carrier can inform you which ISDN features can be controlled by code in your country.
This feature allows you to activate the appropriate ISDN function at the terminal, without the need for external access.
Assignment of a digital line to an MSN (078)
This features allows you to assign the MSNs provided by your local carrier to calls made over digital lines.
External line prefix (189)
This setting specifies the prefix for the PABX external lines, for domestic and international calls. By default, the type of a pro-
grammed called is not specified.
External number registration (191)
To use the attendant feature, each external number must be registered to a specific slot.
If the prefix (Code 089) for these numbers has already been configured, only the final digits need to be registered.
By default, no digits are specified.
Assigning MSNs to attendants (192)
MSNs registered for each slot (see MSN Extension Assignment for Outgoing External Calls (086)) must be assigned to exten-
sions, call groups or a mailbox using a virtual EVM port (see Mailboxes assignments (203)) designated for answering calls dur-
ing a specified period of time.
An extension. Group or EVM virtual port cannot be assigned more than once. A distinctive tone on the handset indicates an
invalid entry.
Service Manual
module's first port can only be a trunk, PP or PMP . It
0
line (075)
0
Configuring the system specifically for the client
Comments about the system's programming codes
bus.
0
Bus) between the S
module and
0
0
Bus.
0
6-273