Figure 30. Adapter installation
Step 8.
Connect any required cables to the adapter.
Attention:
• When you route cables, do not block any connectors or the ventilated space around any of
the fans.
• Make sure that cables are not routed on top of components that are under the PCI riser-card
assembly.
• Make sure that cables are not pinched by the server components.
Step 9.
Install the PCI riser-card assembly (see "Installing a PCI riser-card assembly" on page 75).
Step 10. Perform any configuration tasks that are required for the adapter.
If you have other devices to install or remove, do so now. Otherwise, go to "Completing the installation"
on page 73.
Installing a single / dual port 10GbE SFP+ embedded adapter with
interposer
Use this information to install a single / dual port 10GbE SFP+ embedded adapter with interposer.
Notes:
• To confirm that server supports the adapter that you are installing, see http://www.lenovo.com/us/en/
serverproven/.
• Locate the documentation that comes with the adapter and follow those instructions in addition to
the instructions in this section.
44
Lenovo System x3650 M4 BDInstallation and Service Guide