CIM Information
Prefix: PLAT ID: 0522
User Response
1. If enabling TXT is not required, disable TXT from the Setup Utility.
2. If enabling TXT is required, verify that the TPM is enabled and activated from the Setup Utility.
3. If the problem remains, contact your service representative.
• 8007020f-2582ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (No PCI I/O Space)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020f2582ffff or 0x8007020f2582ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
Complete the following step to solve PCI I/O resource errors:
1. Go to F1 Setup
2. System Settings
3. Device and I/O ports
4. PCI 64 bit Resource and choose enable.
• 80070214-2201ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (TPM Lock)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702142201ffff or 0x800702142201ffff
Severity
362
Lenovo System x3650 M4 BDInstallation and Service Guide