Lenovo x3650 M4 BD 5466 Installation And Service Manual page 407

Hide thumbs Also See for x3650 M4 BD 5466:
Table of Contents

Advertisement

Firmware BIOS (ROM) corruption was detected on the system during POST.
May also be shown as 806f000f22010bff or 0x806f000f22010bff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0850
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page: a.Restart the server. b.At the prompt,
press F3 to recover the firmware.
3. Update the server firmware to the latest level (see Updating the firmware). Important: Some
cluster solutions require specific code levels or coordinated code updates. If the device is part
of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem
goes away.
5. If the problem remains, (trained service technician) replace the system board.
Firmware Error : Sys Boot Status :
• 806f000f-22010cff : CPU voltage mismatch detected on [ProcessorElementName]. (ABR Status)
This message is for the use case when an implementation has detected a CPU voltage mismatch with the
socket voltage.
May also be shown as 806f000f22010cff or 0x806f000f22010cff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
Appendix A. Integrated management module II (IMM2) error messages
393