Lenovo x3650 M4 BD 5466 Installation And Service Manual page 517

Hide thumbs Also See for x3650 M4 BD 5466:
Table of Contents

Advertisement

• 806f060d-040dffff : Array [ComputerSystemElementName] has failed. (Drive 13)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d040dffff or 0x806f060d040dffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
806f070c-2001ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2001ffff or 0x806f070c2001ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
Appendix A. Integrated management module II (IMM2) error messages
503

Advertisement

Table of Contents
loading

Table of Contents