Replacing A Usb Embedded Hypervisor Flash Device - Lenovo x3650 M4 BD 5466 Installation And Service Manual

Hide thumbs Also See for x3650 M4 BD 5466:
Table of Contents

Advertisement

Figure 118. USB embedded hypervisor flash device removal
Step 8.
If you are instructed to return the hypervisor memory key, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Note: You must configure the server not to look for the hypervisor USB drive. See "Configuring the
server" on page 84 for information about disabling hypervisor support.

Replacing a USB embedded hypervisor flash device

Use this information to replace a USB embedded hypervisor flash device.
To install a USB hypervisor memory key in the server, complete the following steps:
Step 1.
Read the safety information that begins on page "Safety" on page v and "Installation guidelines"
on page 30.
Step 2.
Turn off the server (see "Turning off the server" on page 19) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables as necessary to replace the device.
Step 3.
Remove the server top cover (see "Removing the server top cover" on page 247).
Step 4.
Rotate the hot-swap rear hard disk drive cage up (see "Rotating the hot-swap rear hard disk
drive cage up" on page 155.
Step 5.
Remove PCI riser-card assembly 1 (see "Removing a PCI riser-card assembly" on page 197).
Step 6.
Locate the USB embedded hypervisor flash device connector on the system board.
190
Lenovo System x3650 M4 BDInstallation and Service Guide

Advertisement

Table of Contents
loading