Lenovo x3650 M4 BD 5466 Installation And Service Manual page 414

Hide thumbs Also See for x3650 M4 BD 5466:
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0036
User Response
1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of
the server), the air baffles are in place and correctly installed, and the server cover is installed
and completely closed.
2. Make sure that the heat sink for microprocessor n is installed correctly.
3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0108-0a01ffff : [PowerSupplyElementName] has Failed. (Power Supply 1)
This message is for the use case when an implementation has detected a Power Supply has failed.
May also be shown as 806f01080a01ffff or 0x806f01080a01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0086
User Response
1. Reseat power supply n.
2. If the power-on LED is not lit and the power-supply error LED is lit, replace power supply n.
3. If both the power-on LED and the power-supply error LED are not lit, see Power problems for
more information. (n = power supply number)
• 806f0108-0a02ffff : [PowerSupplyElementName] has Failed. (Power Supply 2)
This message is for the use case when an implementation has detected a Power Supply has failed.
May also be shown as 806f01080a02ffff or 0x806f01080a02ffff
Severity
Error
Serviceable
400
Lenovo System x3650 M4 BDInstallation and Service Guide