Lenovo x3650 M4 BD 5466 Installation And Service Manual page 340

Hide thumbs Also See for x3650 M4 BD 5466:
Table of Contents

Advertisement

Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
80010204-1d02ffff : Numeric sensor [NumericSensorElementName] going low (lower critical)
has asserted. (Fan 1Ab Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d02ffff or 0x800102041d02ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
80010204-1d03ffff : Numeric sensor [NumericSensorElementName] going low (lower critical)
has asserted. (Fan 2Aa Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d03ffff or 0x800102041d03ffff
326
Lenovo System x3650 M4 BDInstallation and Service Guide