Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
•
80010204-1d07ffff : Numeric sensor [NumericSensorElementName] going low (lower critical)
has asserted. (Fan 4 Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d07ffff or 0x800102041d07ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
•
80010204-1d08ffff : Numeric sensor [NumericSensorElementName] going low (lower critical)
has asserted. (Fan 5 Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d08ffff or 0x800102041d08ffff
Severity
Error
Serviceable
Yes
Appendix A. Integrated management module II (IMM2) error messages