one of these parts, contact a service technician.
Attention: During normal operation, each power-supply bay must contain either a power supply or
power-supply filler for proper cooling.
To replace a hot-swap ac power supply, complete the following steps.
Step 1.
Read the safety information that begins on page "Safety" on page v and "Installation guidelines"
on page 30.
Step 2.
Touch the static-protective package that contains the hot-swap power supply to any unpainted
metal surface on the server; then, remove the power supply from the package and place it on
a static-protective surface.
Step 3.
If you are installing a hot-swap power supply into an empty bay, remove the power-supply filler
panel from the power-supply bay. Meanwhile, if you are replacing a failed hot-swap power supply,
remove it from the bay.
Figure 60. Power supply installation
Step 4.
Grasp the handle on the rear of the power supply and slide the power supply forward into the
power-supply bay until it clicks. Make sure that the power supply connects firmly into the
power-supply connector.
Step 5.
Connect the power cord for the new power supply to the power-cord connector on the power
supply.
Step 6.
Route the power cord through the cable retainer clip so that it does not accidentally become
disconnected.