Lenovo System x3650 M4 BD Product Manual

Hide thumbs Also See for System x3650 M4 BD:

Advertisement

System x3650 M4 BD

Product Guide

The System x3650 M4 BD server offers a cost-effective, high-capacity storage solution with exceptional
energy-smart design, leadership virtualization, and powerful systems management. It supports up to two
Intel Xeon processor E5-2600 v2 family processors and high-density memory designs with 16 DDR3 DIMM
slots. This 2U server is built on X-Architecture®, and it consolidates storage and server into one system,
offers easy management, and saves floor space and power consumption, costing less money than
traditional enterprise offerings.
Suggested use: Big data, email and collaboration applications, databases, virtualization and cloud, virtual
desktops, and virtual storage.
The following figure shows the System x3650 M4 BD.
Figure 1. The System x3650 M4 BD
Did you know?
The System x3650 M4 BD server is designed to provide exceptional value and flexibility to meet "big data"
requirements and general business and storage-demanding applications, with up to 84 TB of storage space
in a dense 2U form factor, Intel Xeon E5-2600 v2 product family processors, two DIMMs per channel
running at up to 1866 MHz, and 80 PLUS certified power supplies.
The flexible onboard Ethernet solution provides three integrated Gigabit Ethernet ports, one dedicated
systems management port, and an optional embedded 10 GbE ports.
Comprehensive systems management tools with the next-generation Integrated Management Module II
(IMM2) make it easy to deploy, integrate, service, and manage.
Click here to check for updates
System x3650 M4 BD
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo System x3650 M4 BD

  • Page 1: Product Guide

    Figure 1. The System x3650 M4 BD Did you know? The System x3650 M4 BD server is designed to provide exceptional value and flexibility to meet "big data" requirements and general business and storage-demanding applications, with up to 84 TB of storage space in a dense 2U form factor, Intel Xeon E5-2600 v2 product family processors, two DIMMs per channel running at up to 1866 MHz, and 80 PLUS certified power supplies.
  • Page 2: Key Features

    With more flexible configuration options, energy-efficient components, and robust systems management tools, the x3650 M4 BD is an innovative design by Lenovo that can deliver business value over the long term. Scalability and performance...
  • Page 3 The Intel Xeon processor E5-2600 v2 product family offers better performance over the previous generation, while fitting into the same TDP limits. Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw. System x3650 M4 BD...
  • Page 4: Locations Of Key Components And Connectors

    Locations of key components and connectors The following figure shows the front of the server. Figure 2. Front view of the System x3650 M4 BD The following figure shows the rear of the server. Figure 3. Rear view of the System x3650 M4 BD The following figure shows the locations of key components inside the server.
  • Page 5: Standard Specifications

    Figure 4. Inside view of the System x3650 M4 BD (with the rear drive cage removed) Standard specifications The following table lists the standard specifications. Table 1. Standard specifications Components Specification Machine type 5466 Form factor 2U rack. Processor Up to two Intel Xeon processor E5-2600 v2 product family processors with 12 cores (up to 2.4 GHz), 10 cores (up to 2.8 GHz), eight or six cores (up to 2.6 GHz) or four cores (up to 2.5...
  • Page 6: Specification

    Optional service upgrades (country-specific) are available through ServicePac® offerings: 4- support hour or 2-hour response time, 8 hours fix time, one-year or two-year warranty extension, remote technical support for Lenovo hardware and selected Lenovo and third-party (Linux) software. Dimensions Height: 86 mm (3.4 in.), width: 447 mm (17.6 in.), depth: 749 mm (29.5 in.) Weight Minimum configuration: 16.4 kg (36.2 lb), maximum: 29.8 kg (65.7 lb)
  • Page 7: Standard Models

    Important Notices Rack Installation Instructions Documentation CD containing Installation and User's Guide Rail kit (static rails, non-sliding; no cable management arm included) One 2.8 m, 10A/100-250 V, C13 to IEC 320-C14 rack power cable Standard models System x3650 M4 BD...
  • Page 8: Express Models

    * x in the Machine Type Model (MTM) represents a country-specific letter (for example, the EMEA MTM is 5466-A2G, and the US MTM is 5466-A2G). Ask a Lenovo representative for specifics. † Processor detail: Processor quantity and model, number of cores, core speed, L3 cache, memory speed, and TDP.
  • Page 9: Processor Options

    * x in the Machine Type Model (MTM) represents a country-specific letter (for example, the EMEA MTM is 5466-A2G, and the US MTM is 5466-A2G). Ask a Lenovo representative for specifics. † Processor detail: Processor quantity and model, number of cores, core speed, L3 cache, memory speed, and TDP.
  • Page 10 Lenovo provides service and support worldwide. The System x3650 M4 BD supports DDR3 memory. The server supports up to eight DIMMs when one processor is installed and up to 16 DIMMs when two processors are installed. Each processor has four memory channels, and there are two DIMMs per channel.
  • Page 11 * Maximum quantity that is supported is shown for two processors installed. ** Rated speed is not supported. Memory DIMMs always operate at speeds lower than rated. The following table lists the memory options that are available for the x3650 M4 BD server. Table 6. Memory options System x3650 M4 BD...
  • Page 12: Feature Description

    A3QL 16GB (1x16GB, 2Rx4, 1.5V) PC3-14900 CL13 ECC 16 (8 per CPU) DDR3 1866MHz LP RDIMM LRDIMMs 46W0761 A47K 32GB (1x32GB, 4Rx4, 1.5V) PC3-14900 CL13 ECC 16 (8 per CPU) DDR3 1866MHz LP LRDIMM Internal storage System x3650 M4 BD...
  • Page 13: Controllers For Internal Storage

    The following table (Parts 1 and 2) lists the storage controllers and the additional options that are used for the internal storage of the x3650 M4 BD server. Table 8. RAID controllers and HBAs for internal storage (Part 1: 6 Gbps SAS) System x3650 M4 BD...
  • Page 14 512MB Cache/RAID 5 Upgrade (81Y4484). † The ServeRAID M5100 Series RAID 6 Upgrade (81Y4546) requires 512 MB or 1 GB cache upgrades. Table 8. RAID controllers and HBAs for internal storage (Part 2: 12 Gbps SAS) System x3650 M4 BD...
  • Page 15 ServeRAID M1115 SAS HDD Yes* ServeRAID M1215 SATA HDD Yes* SATA SSD Yes* ServeRAID M5110 SAS HDD Yes* ServeRAID M5210 SATA HDD Yes* SATA SSD Yes* N2115 SAS HDD Yes* SATA HDD Yes* SATA SSD Yes* System x3650 M4 BD...
  • Page 16 Eight internal 6 Gbps SAS/SATA ports Up to 6 Gbps throughput per port Two x4 mini-SAS internal connectors (SFF-8087) Supports connections to SAS/SATA HDDs and SATA SSDs Optimized for SSD performance No RAID support PCIe 3.0 x8 host interface System x3650 M4 BD...
  • Page 17: Internal Drive Options

    Zero Controller Cache, no battery/flash backup Optional support for self-encrypting drives (SEDs) with MegaRAID SafeStore (with RAID 5 upgrade) Fixed stripe size of 64 KB For more information, see the list of Lenovo Press Product Guides in the RAID adapters category: http://lenovopress.com/systemx/raid Internal drive options The following table lists the hard disk drive options for the internal disk storage of the x3650 M4 BD server.
  • Page 18: Internal Backup Units

    3.5" SATA Hot-Swap SSDs - Entry 00FN352 AS0K 240GB SATA 3.5" MLC HS Entry SSD 00FN357 AS0L 480GB SATA 3.5" MLC HS Entry SSD 00FN362 AS0M 960GB SATA 3.5" MLC HS Entry SSD Internal backup units System x3650 M4 BD...
  • Page 19: Optical Drives

    Integrated PHY for 10/100/1000 Mbps for multispeed, full, and half-duplex auto-negotiation IEEE 802.3x and 802.3z compliant flow control support with software-controllable Rx thresholds and Tx pause frames Automatic cross-over detection function (MDI/MDI-X) IEEE 1588 protocol and 802.1AS implementation System x3650 M4 BD...
  • Page 20 Message Signal Interrupt Extension (MSI-X) Receive Side Scaling (RSS) for Windows Scalable I/O for Linux environments (IPv4, IPv6, and TCP/UDP) Support for packets up to 9.5 KB (jumbo frames) The following table lists additional supported network adapters. System x3650 M4 BD...
  • Page 21 * The embedded adapter is installed in a regular PCIe slot (slot 1) through an interposer that is included with the adapter. ** Require SFP+ optical transceivers or DAC cables that must be purchased separately. For more information, see the list of Lenovo Press Product Guides in the Ethernet and IB adapters category: http://lenovopress.com/systemx/networkadapters System x3650 M4 BD...
  • Page 22: Storage Host Bus Adapters

    00AE916 A5M1 N2226 SAS/SATA HBA for System x For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category: http://lenovopress.com/systemx/hba PCIe SSD adapters The x3650 M4 BD server supports the High IOPS SSD adapters that are listed in the following table.
  • Page 23: Power Supplies

    USB socket inside the server. The following table lists the virtualization options. Table 17. Virtualization options Part Feature Description Maximum number code supported 41Y8298 A2G0 Blank USB Memory Key for VMware ESXi Downloads 41Y8385 A584 USB Memory Key for VMware ESXi 5.5 Remote management System x3650 M4 BD...
  • Page 24: Light Path Diagnostics Panel

    The following table lists the remote management option. Table 18. Remote management option Part Feature Description Maximum number code supported 90Y3901 A1ML Integrated Management Module Advanced Upgrade Light path diagnostics panel System x3650 M4 BD...
  • Page 25: Supported Operating Systems

    (light path level 3), for example, the DIMM error LED on the system board. x3650 M4 BD offers basic light path diagnostics, as shown in the following figure. Figure 5. Basic (level 1) light path Supported operating systems System x3650 M4 BD...
  • Page 26: Physical And Electrical Specifications

    SUSE Linux Enterprise Server 12 with XEN VMware vSphere 5.1 (ESXi) VMware vSphere 5.5 (ESXi) For the latest information about the specific versions and service levels that are supported and any other prerequisites, see the ServerProven® website: http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml Physical and electrical specifications System x3650 M4 BD...
  • Page 27: Warranty Options

    The x3650 M4 BD has a three-year warranty with 24x7 standard call center support and 9x5 Next Business Day onsite coverage. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time,...
  • Page 28 Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, visit the Lenovo Services website: https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do...
  • Page 29: Regulatory Compliance

    Lenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.
  • Page 30 One of the available cache upgrades (81Y4484, 81Y4487, or 81Y4559) is required for the M5120 adapter operations, and it must be purchased together with the controller. For more information, see the Lenovo Press Product Guide ServeRAID M5120 SAS/SATA Controller for System x, TIPS0858: http://lenovopress.com/tips0858...
  • Page 31 EXP2512 Storage Enclosure 610024X EXP2524 Storage Enclosure Lenovo ThinkServer SA120 support For details about supported drives and cables for the Lenovo ThinkServer SA120, see the Lenovo Press Product Guide: http://lenovopress.com/tips1234 EXP2512 and EXP2524 support The external SAS cables listed in the following table support connectivity between external expansion enclosures and the controller.
  • Page 32: External Disk Storage Systems

    00NC567 900GB 10,000 rpm 6Gb SAS 2.5" HDD 00NC569 1.2TB 10,000 rpm 6Gb SAS 2.5" HDD 2.5" SAS HS SSDs 00NC573 200GB 6Gb SAS 2.5" SSD 00NC575 400GB 6Gb SAS 2.5" SSD External disk storage systems System x3650 M4 BD...
  • Page 33: External Backup Units

    6195LEF IBM Storwize V7000 3.5-inch Storage Expansion Unit 6195SEF IBM Storwize V7000 2.5-inch Storage Expansion Unit For more information, see the list of Lenovo Press Product Guides in the System Storage category: http://lenovopress.com/systemx/externalstorage External backup units System x3650 M4 BD...
  • Page 34: Top-Of-Rack Ethernet Switches

    See the IBM System Storage Interoperation Center (SSIC) for further information. For more information, see the list of Lenovo Press Product Guides in the Backup units category: http://lenovopress.com/systemx/tape Top-of-rack Ethernet switches...
  • Page 35: Uninterruptible Power Supply Units

    40 Gb top-of-rack switches 7159BFX Lenovo RackSwitch G8332 (Front to Rear) 7159BRX Lenovo RackSwitch G8332 (Rear to Front) For more information, see the list of Lenovo Press Product Guides in the Top-of-rack switches category: http://lenovopress.com/systemx/tor Uninterruptible power supply units System x3650 M4 BD...
  • Page 36: Power Distribution Units

    6000VA LCD 4U Rack UPS (230 V) 53959KX 11000VA LCD 5U Rack UPS (200V/208V/230V) For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category: http://lenovopress.com/systemx/power Power distribution units The server supports attachments to the power distribution units (PDUs) that are listed in the following table.
  • Page 37 DPI 63amp/250 V Front-end PDU with IEC 309 2P+Gnd connector 39Y8938 30 amp/125 V Front-end PDU with NEMA L5-30P connector 39Y8939 30 amp/250 V Front-end PDU with NEMA L6-30P connector 39Y8940 60 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector System x3650 M4 BD...
  • Page 38: Rack Cabinets

    0U 12 C19/12 C13 60A 3 Phase PDU 46M4143 0U 12 C19/12 C13 32A 3 Phase PDU For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category: http://lenovopress.com/systemx/power Rack cabinets System x3650 M4 BD...
  • Page 39: Rack Options

    47U 1200mm Deep Static Rack 93634DX PureFlex™ System 42U Expansion Rack 93634CX PureFlex System 42U Rack For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category: http://lenovopress.com/systemx/rack Rack options System x3650 M4 BD...
  • Page 40: Lenovo Financial Services

    46M5383 5341 Virtual Media Conversion Option Gen2 (VCO2) 46M5382 5340 Serial Conversion Option (SCO) For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category: http://lenovopress.com/systemx/rack Lenovo Financial Services System x3650 M4 BD...
  • Page 41: Related Publications And Links

    For you, this dedication provides a high-quality, easy, and positive financing experience. For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website: http://www.lenovo.com/services_warranty/us/en/financial_services.html...
  • Page 42 Related product families Product families related to this document are the following: 2-Socket Rack Servers System x3650 M4 BD...
  • Page 43 Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment.
  • Page 44 Trademarks Lenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at http://www.lenovo.com/legal/copytrade.html. The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo®...

Table of Contents