Identify a Faulty DIMM

When servicing the components in this section, unplug the AC power cords and use ESD
protection.
To identify a faulty DIMM, use the DIMM Fault Remind circuitry that is located on the
memory riser (MR) card.
Note -
remind test cirduit.
For serviceability considerations, see
Before You Begin
For DIMM designation information, see
For reference information, see
1.
Use Oracle ILOM to identify the failed DIMM in the system. See
Hardware Faults" on page 35
Oracle ILOM can provide the memory riser card and DIMM designations for the failed DIMM.
2.
If Oracle ILOM is showing multiple DIMMs in a failed state, see
a Multi-DIMM Failure State" on page
3.
Identify the memory riser card that contains the failed DIMM. See
Failed Memory Riser Card, DIMM, or CPU" on page
4.
Remove the MR card. See
Once power is removed from the server, you have 10 minutes to use the DIMM fault
"Remove a Memory Riser Card" on page