This section explains how to install and set up the projector. If you are familiar with the projector and want to quickly
set it up for temporary use, follow the Quick Setup instructions below. For a more complete setup, follow the
instructions and guides covered in the remaining subsections.
NOTE: The lens is not installed for shipping. For instructions on how to install or replace a lens, refer to 4.5,
Replacing the Lens.
2.1

Quick Setup

Downloaded From projector-manual.com Christie Manuals
Follow these steps for quick setup of the projector in a standard floor mount position.
Use either the remote or built-in keypad to work with the projected image.
STEP 1 '
Position the Projector
Set the projector at the expected throw distance (projector-to-screen distance) and
vertical position. See 2.3, Projector Position and Mounting and Appendix D. Make
sure that the projector is level from side-to-side (see Section 2.9, Leveling).
STEP 2 '
Connect a Source
Locate the main input panel at the rear of the projector and connector your source to
the appropriate input:
◊ INPUT 1 (upper right area) – RGB input via BNC connectors.
◊ INPUT 2 (left of BNCs) – digital or analog signals (DVI-I) from a computer.
◊ INPUT 3 (upper middle area) – composite video.
◊ INPUT 4 (upper middle area) – S-video.
◊ INPUT 5 (lower area of Roadster S
module which can accept serial digital.
◊ INPUT 6 (lower area ) – for optional input modules (see Appendix F).
STEP 3 '
Connect to Power
Connect the projector's line cord to the AC receptacle at the lower rear corner on the
rear the projector, and to proper AC. Use only the line cord provided with the
projector. Power requirements are shown below. Complete information is in Section 6.
◊ The Roadster S
◊ The Roadster S
amps @ 200 VAC.
within the specified voltage and power range. See Section 6.
Installation & Setup
+
12K requires 200-240 VAC, 50-60 Hz, 13.5 amps @ 200 VAC.
+
16K and the Mirage S
WARNING
Do not attempt operation if the AC supply and cord are not
+
panel) – a factory-installed Dual SD/HD-SDI
+
14K require 200-240 VAC, 50-60 Hz, 17.7
Roadster / Mirage S+ User's Manual
S e c t i o n 2
2-1