RS232 SERIAL INTERFACE (WITH LOOP THROUGH) -
projectors to be remotely controlled by a computer or controller,
RS422 INTERFACE -
an RS422 compatible computer or controller (such as the Two-Way Controller
accessory).
AC Power Input and Monitoring
AC LINE CORD INPUT -
line cord provided with the projector. See Section 5. Before unplugging, wait until
the main blower turns off or the LCD status reads Power Off.
Model
Roadster S+12K
Roadster S+16K
MirageS+14K
Do not attempt operation if the AC supply is not within the
specified voltage and power range. Use the specified line cord.
VOLTMETER -
Displays incoming voltage level reaching the projector.
SWITCH/BREAKER -
a power switch for the ballast 2) It protects against excessive AC conditions
(15A or more for Roadster S+12K, and 20A or more for
RoadsterS+16K/Mirage S+14K). If the projector is faulty or excessive AC is
detected, the breaker will "trip" to OFF in order to prevent damage. Try
moving the breaker ON again - if the breaker continues to trip OFF, this
indicates a major fault and the AC problem must be resolved. Possible causes
might include shorts, damage to lamp cables, or excessive AC.
Note: This switch does not power up the projector or start the lamp. You must press
on the keypad.
Two Status Displays:
2-DIGIT STATUS/ERROR CODE WINDOW -
display is adjacent to the built-in keypad. During normal operation, the
"Power" light is steady yellow and indicates "on". When the status of the
projector changes, the LED displays a 2-digit code number representing the
projector's new status. In addition to the numeric readout, there are two
decimal points in the display: the right decimal point flashes when the projector
receives a command, and the left point flashes when the projector sends a
command.
LCD STATUS DISPLAY WINDOW -
current system status (such as an error). During normal operation, this display
indicates Power On and includes the frequencies of the vertical and horizontal
syncs. The display also shows if the On Screen Display (OSD, or menu system)
is on or off. The LCD displays the message Power Off when the breaker is on
but the lamp is off.
Allows one or more projectors to be remotely controlled by
Use the AC supply specified, and always use the
AC Power Specifications
200-240 VAC, 50-60 Hz, max. 15 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 20 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 20 amps @ 200VAC
WARNING
The breaker on the rear panel serves two purposes: 1) It is
This LED (light emitting diode)
Displays a text message describing the
Roadster / Mirage S+ User's Manual
OPERATION
Allows one or more
3-3