Christie Mirage S+14K User Manual page 101

Hide thumbs Also See for Mirage S+14K:
Table of Contents

Advertisement

Downloaded From projector-manual.com Christie Manuals
Table 3.4. System Error Codes
Code
Description
GENERAL
12
Software error. Contact dealer/factory.
13
CRC error in flash ROM. Download new software.
14
Engineering-only programming is complete. Call Christie, replace TIPM.
15
Attempting to download s/w code without being in boot mode
16
Invalid interrupt. Power off/on. If persists, contact dealer/factory.
17
User has forced system to stay in boot mode
18
Attempting to program boot mode without jumper
LAMP / BALLAST
20
The lamp is unexpectedly on (likely a ballast and/or wiring problem)
21
Lamp airflow is low; overheating imminent
23
Cannot read valid ballast ID
26
Lamp door is open, or lamp is not installed (interlock)
27
Lamp cannot ignite
28
Lamp has turned off unexpectedly
29
Lamp ballast is overheated
2D
Unknown or invalid Ballast ID, usually caused by faulty ballast cable or faulty ballast.
POWER & COOLING
46
Red DMD heatsink has overheated
47
Green DMD heatsink has overheated
48
Blue DMD heatsink has overheated
49
Prism has overheated (not applicable to Roadster S
4C
Projector has shut down due to critical error
C0
Lamp cannot ignite due to blower failure
C6
TIPM is overheated
C7
TIPM is approaching the over-temperature threshold
53
Card cage fan failed (Fan 3) NOTE: may be connected as fan 4 or 5
54
LVPS fan failed fan failed (Fan 4) NOTE: may be connected as fan 3 or 5
55
Exhaust fan failed (Fan 5) NOTE: may be connected as fan 3 or 4
56
Prism fan failed (Fan 6)
57
Red DMD fan failed (Fan 7)
TIPM (10-bit Image Processor)
60
Boot code CRC failed
61
Unable to program DigMux PLD
62
Unable to program Control PLD
63
Unable to program Bubks PLD
64
Unrecognized ROM type
65
Write to flash ROM failed
66
General TIPM failure
67
Downloaded code will not fit into ROMs
68
Communication failure with scaler on TIPM
Keypad and EEPROM
70
Unable to access EEPROM on the built-in keypad
71
EEPROM memory on the built-in keypad has reinitialized
PANEL DRIVER or FORMATTERS
80
Unrecognized Panel Driver
81
Unable to program device on Panel Driver
82
TI flash download failure
83
TI flash download failure
84
TI flash download failure
2
85
TI - I
C write failure
86
One or more Formatters is not responding — probable Formatter s/w fault
87
Formatter reports consecutive RDRAM failures
88
Red modular Formatter communication failure
89
Green modular Formatter communication failure
8A
Blue modular Formatter communication failure
93
Modular Formatter architecture error
94
Modular Formatter / DMD mismatch
95
Modular Formatter sequence mismatch
MISCELLANEOUS
A0
Unable to program the optional interface module
A1
Unable to power the optional interface module
A2
Unable to program the Dual Slot Backplane Module (DSBP)
A3
Unable to program the warping module option (ChristieTWIST)
f you encounter a system error, clear it with
powering it off and on again (cooling if necessary). Contact dealer/factory if error persists.
The specific code number identifies the source of the error detected, and is
particularly useful in cases wher8e the projector is too far away to read the
accompanying text message in the LCD status display window. For example, the
code "21" means the lamp could not be turned on. Error codes for this projector are
listed in Table 3.4.
+
12K)
Exit
Exit
. If necessary, try resetting the projector by
Roadster / Mirage S+ User's Manual
OPERATION
3-67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Roadster s+16kRoadster s+12sRoadster s+12k