Stopping Ia770; Backing Up System Files - Avaya g700 Installation And Upgrades

Media gateway and media server
Hide thumbs Also See for g700:
Table of Contents

Advertisement

Stopping IA770

Note:
If you are using the Avaya Installation Wizard (IW) to upgrade the server, skip this
Note:
procedure. The IW will execute the stop command automatically.
To stop IA770:
1. Type telnet 192.11.13.6 and press Enter.
2. Log in as craft or dadmin.
Note:
You must enter the commands in the next two steps using upper-case as
Note:
indicated.
3. Type stop -s Audix, and press Enter to shut down AUDIX. Note that the "A" in Audix
must be capitalized.
The shutdown takes a few minutes.
4. Type watch /VM/bin/ss, and press Enter to monitor the shutdown.
The watch command automatically refreshes every few seconds. When the shutdown is
complete, you see only the voicemail and audit processes. For example:
voicemail:(10)
audit http:(9)
Press Ctrl+C to break out of the watch command.
5. Type /vs/bin/util/vs_status, and press Enter to verify that AUDIX is shut down.
When AUDIX is shut down, you see the message
Voice System is Down.
!
Important:
After upgrading an S8300 media server, you must upgrade the G700 or G350
Important:
media gateway firmware and media module firmware before restarting IA770.

Backing up system files

For releases 1.2.0 through 1.3.9, this backup is optional but recommended in case there is a
need to back out of the upgrade.
Preparing for the upgrade on-site