Connecting The 1152A1 Pdu Cables - Avaya g700 Installation And Upgrades

Media gateway and media server
Hide thumbs Also See for g700:
Table of Contents

Advertisement

To connect the 1152A1 PDU
!
CAUTION:
The 1152A1 PDU has no ON/OFF switch. To connect or disconnect power to the
CAUTION:
1152A1 PDU, simply insert or remove the power cable from the AC power
receptacle on the rear of the 1152A1 PDU.
1. Plug a power cord into the power socket on the rear of the 1152A1 Power Distribution Unit.
2. Plug the other end of the power cord into the power receptacle.
The 1152A1 PDU powers up, and the internal fans begin operating.
The 1152A1 PDU then runs through its Power On Self Test (POST), which takes less than
10 seconds. During the test, all the ports on the unit are disabled and the LEDs light up. For
more information on the test, refer to the user's guide that comes with the unit.

Connecting the 1152A1 PDU cables

All of the ports on the front of the 1152A1 PDU are configured as data route-through ports for all
data wires (pins 1, 2, 3 and 6).
1
2
3
'DWD
3RZHU
'DWD
Use a standard CAT5, CAT6 or CAT6e straight-through Ethernet cable (not supplied), including
all 8 wires (4 pairs) as shown in
page 346.
Figure 23: Connecting telephones and other end devices to the 1152A1 PDU
Ethernet
Switch/Hub
7
8
4
5
6
9
10
Connecting cables to telephones and other end devices
$3RZHU'LVWULEXWLRQ8QLW
RJ-45 IN
data
1
1
data
2
2
data
3
3
spare
4
4
spare
5
5
data
6
6
spare
7
7
spare
8
8
Installation and wiring of telephones and power supplies
13
14
11
12
15
16
17
RJ-45 OUT
1
2
3
4
5
6
7
8
19
20
18
21
22
23
24
End Device
data
1
data
2
data
3
DC +
4
DC +
5
data
6
DC -
7
DC -
8
Issue 8.1 June 2005
$3RZHU
'LVWULEXWLRQ8QLW