Installing And Wiring Telephone Power Supplies - Avaya g700 Installation And Upgrades

Media gateway and media server
Hide thumbs Also See for g700:
Table of Contents

Advertisement

Figure 20: 808A Emergency Transfer Panel
Figure notes:
1. 808A emergency transfer panel
2. Circuit start selection switches

Installing and wiring telephone power supplies

This section provides information and wiring examples of installation procedures for various
telephone and console power supplies. These are examples only and actual wiring procedures
may vary at each site.
Note:
Refer to the Installation for Adjuncts and Peripherals for Avaya Communication
Note:
Manager, 555-233-116, to install the necessary peripheral equipment.
The power is provided to telephones or consoles either centrally or locally.
Installation and wiring of telephones and power supplies
EMERGENCY
TRANSFER
PANEL
POWER
TRUNK/TEST SWITCHES
CIRCUIT
1
TRUNK OPTION
1
2
LOOP
GROUND
1
3
START
START
2
2
4
5
3
6
BOTH SWITCHES MUST BE
7
THROWN TO ACTIVATE
4
8
TRUNK OPTION
9
5
10
12
TRANSFER TEST SWITCH
NORMAL
ACTIVATED
OPERATION
TRUNK IDENTIFICATION
TRUNK
EXT
LOC
LINE
808A
led808a LJK 040896
3. Trunk identification label
4. 25-pair male connector