Parameter lists

4.1 Parameter lists
The inverter is factory-set to display only the simple mode parameters.
Set Pr. 160 "extended function selection" as required.
Parameter
Name
Extended function
160
selection
CAUTION
• The blacked out parameters in the table below indicate simple mode parameters.
• The shaded parameters in the table allow its setting to be changed during operation even if "0" (factory
setting) is set in Pr. 77 (parameter write disable selection).
• *: Accessible when Pr. 77 = 801.
Parameter
Function
No.
0
Torque boost (manual)
1
Maximum speed
2
Minimum speed
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
Basic functions
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
10
DC injection brake operation speed
11
DC injection brake operation time
Standard
12
DC injection brake voltage
operation
13
Starting speed
functions
15
Jog speed setting
16
Jog acceleration/deceleration time
17
MRS input selection
19
Base frequency voltage
Acceleration/deceleration reference
20
speed
21
Acceleration/deceleration time increments
22
Torque restriction level
Operation
selection
24
Multi-speed setting (speed 4)
functions
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
28
Multi-speed input compensation
Factory
Setting
Setting
Range
0
Accessible to only the simple mode parameters.
0
1
Accessible to all parameters.
Name
Setting Range
0 to 30%
0 to 3600r/min
0 to 3600r/min
20 to 200Hz
0 to 3600r/min
0 to 3600r/min
0 to 3600r/min
0 to 3600s/0 to
360s
0 to 3600s/0 to
360s
0 to 500A
0 to 1500r/min,
9999
0 to 0.5s
0 to 30%
0 to 1500r/min
0 to 1500r/min
0 to 3600s/0 to
360s
0, 2
0 to 1000V, 8888,
9999
1 to 3600r/min
0, 1
0 to 400%
0 to 3600r/min,
9999
0 to 3600r/min,
9999
0 to 3600r/min,
9999
0 to 3600r/min,
9999
0, 1
78
Remarks
Minimum
Refer
Setting
Factory Setting
Increments
3%/2%/1%
(2.2K/
0.1%
3.7K, 7.5K/
15K or more)
1r/min
1800r/min
1r/min
0r/min
0.01Hz
60Hz
1r/min
1800r/min
1r/min
750r/min
1r/min
150r/min
5s/15s
0.1s/0.01s
(3.7K or less
/7.5K or less)
5s/15s
0.1s/0.01s
(3.7K or less
/7.5K or less)
Rated inverter
0.01A
output current
0.1r/min
15r/min
0.1s
0.5s
0.1%
1%
0.1r/min
15r/min
0.1r/min
150r/min
0.1s/0.01s
0.5s
1
0
0.1V
9999
1r/min
1800r/min
1
0
0.1%
150%
1r/min
9999
1r/min
9999
1r/min
9999
1r/min
9999
1
0
Custo
mer
To
Setting
89
89
89
90
90
90
90
91
91
93
95
95
95
97
98
98
98
90
91
91
100
90
90
90
90
101