Communication functions (Pr. 117 to Pr. 124)
Instruction
No.
Item
Second
parameter
13
changing
(Code
FF=1)
REMARKS
For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an inverter reset or
all clear is performed.
<Error code list>
The corresponding error code in the following list is displayed if an error is detected in any communication request
data from the computer.
Error Code
Error Item
H0
Computer NAK error
H1
Parity error
H2
Sum check error
H3
Protocol error
H4
Framing error
H5
Overrun
H6
H7
Character error
H8
H9
HA
Mode error
HB
Instruction code error
HC
Data range error
HD
HE
HF
Code
When reading/setting the bias/gain (data code H5E to H61, HDE to HE1)
parameters
H6C
H00: Speed/torque
H01: Analog
H02: Analog value of terminal (When written, the data value is any 4-digit
HEC
value.)
The number of errors consecutively detected in
communication request data from the computer is
greater than the allowed number of retry times.
The parity check result does not match the
specified parity.
The sum check code in the computer does not
match that of the data received by the inverter.
Data received by the inverter is in the wrong
protocol, data receive is not completed within the
given time, or CR and LF are not as set in the
parameter.
The stop bit length differs from the initial setting.
New data has been set by the computer before the
inverter completes receiving the preceding data.
The character received is invalid (other than 0 to 9,
A to F, control code).
Parameter write was attempted in other than the
computer link operation mode or during inverter
operation.
The specified command does not exist.
Invalid data has been specified for parameter,
running frequency write, etc.
Description
Error Definition
150
Number
of Data
Digits
2 digits
Inverter Side Operation
Brought to an alarm stop (E.
PUE) if error occurs
continuously more than the
allowable number of retry
times.
Does not accept receive
data but is not brought to
alarm stop.
Does not accept or receive
data but is not brought to
alarm stop.