Cyclic operation mode setting
50%ED torque
<2.2 to 55 (3 to 75) [kW (HP)]>
Torque(%)
100
2.2kW to 55kW (3HP to 75HP)
50
33
0
900
1800
(Caution 1)
CAUTION
1. The maximum speeds are 1) 2.2kW to 7.5kW (3HP to 10HP): 3600r/min, 2) 15kW to 22kW (20HP to
30HP): 3000r/min, and 3) 37kW to 55kW (50HP to 75HP): 1950r/min.
2. 50%ED continuously repeated operation can be performed at the cycle time of 10 minutes. Note that
continuous operation can be performed for a maximum of 5 minutes.
Pr. 802
Refer to Pr. 10 to Pr. 12 (page 95).
Pr. 803
Refer to Pr. 22 (page 100).
Operation selection functions 4 (Pr. 800 to Pr. 809)
1800r/min (60Hz) torque reference
Speed[r/min]
3600
Continuous operation mode setting
Continuous operation torque
<2.2 to 55 (3 to 75) [kW (HP)]>
Torque(%)
100
82
33
0
180
600
1800
183
2.2kW to 55kW (3HP to 75HP)
Speed[r/min]
3600
(Caution 1)
4