Biases And Gains Of Speed Setting Terminals (Speed Setting No. 2, Torque Command No. 3, Multi Function No. 1 Terminal) (Pr. 902 To Pr. 905, Pr. 917 To Pr. 920) - Mitsubishi Electric FR-V560 Instruction Manual

Vector inverter
Table of Contents

Advertisement

Calibration functions (Pr. 900 to Pr. 920)
4.41.2 Biases and gains of speed setting terminals
(speed setting terminal 2, torque command terminal 3, multi function terminal 1)
(Pr. 902 to Pr. 905, Pr. 917 to Pr. 920
The "bias" and "gain" functions are designed to adjust the relationships between the externally input 0-10V
setting input signal and output speed to set the output speed.
Using Pr. 902, set the bias speed at 0V.
(1800r/min)
(150%)
-10V
Parameter
902
Speed setting No. 2 bias
903
Speed setting No. 2 gain
904
Torque command No. 3 bias *1
905
Torque command No. 3 gain *1
917
No. 1 terminal bias (speed) *2
918
No. 1 terminal gain (speed) *2
No. 1 terminal bias
919
(torque/magnetic flux) *1
No. 1 terminal gain
920
(torque/magnetic flux) *1
*1 Factory settings may differ because of calibration parameters.
*2 For calebration of forward/rotation speed restriction, PID control deveation, and measured value.
Speed Command/Speed
(Pr. 807, Pr. 868, Pr. 73)
Calibrati
Parameter
on
Terminal
Speed
(main
speed+a
uxiliary)
902
terminal
2
(+termin
903
al 1)
904
terminal
3
905
917
918
919
terminal
1
920
Gain
Bias
Pr. 905
Pr. 904
Pr. 920
Pr. 919
10V
Setting signal
Inclination is as set in
Pr. 904 (Pr. 919)
and Pr. 905 (Pr. 920).
Name
Factory Setting
0V
10V
0V
10V
0V
10V
0V
10V
Forward/
Reverse
Rotation
Restriction
Speed
Restricti
on
Compen
Magnetic
sation
Override
flux
input
command
(terminal
1)
(Pr. 868)
with
without
with
Encoder
Encoder
Encoder
Speed
(1800r/min)
Bias
Pr. 902
Pr. 917
0
0
0
Setting Range
0r/min
0 to 10V
1800r/min
0 to 10V
0%
0 to 10V
150%
0 to 10V
0r/min
0 to 10V
1800r/min
0 to 10V
0%
0 to 10V
150%
0 to 10V
Torque
Torque
Torque
Torque
restriction
command
bias
(Pr. 810)
(Pr. 804)
(Pr. 840)
(regenera
tive
torque
restriction
(Pr. 868))
202
without
Condi-
tional PLC
SSC
Encoder
)
Torque
Position
Factory setting
Gain
400%
Setting signal
10V
3600r/min
0 to 3600r/min
0 to 3600r/min
0 to 400%
0 to 400%
0 to 3600r/min
Extended mode
0 to 3600r/min
0 to 400%
0 to 400%
Magnetic
PID Control
Flux
(Pr. 128 to Pr. 134)
Magnetic
Deviation Set point
command
(Pr. 868)
Pr. 903
Pr. 918
Remarks
Process
value

Advertisement

Table of Contents
loading