Download  Print this page

Additional Function 2 (pr. 252, Pr. 253); Override Bias, Gain (pr. 252, Pr. 253); Power Failure Stop Functions (pr. 261 To Pr. 266); Power-failure Deceleration Stop Function (pr. 261 To Pr. 266) - Mitsubishi Electric FR-V560 Instruction Manual

Vector inverter.
Hide thumbs

Advertisement

4.24 Additional function 2 (Pr. 252, Pr. 253)

4.24.1 Override bias, gain (Pr. 252, Pr. 253
When override is selected in Pr. 73 "speed setting signal", the override range of 50% to 150% can be
increased (to between 0% and 200%) as desired.
Parameter
Name
252
Override bias
253
Override gain
Related parameters
• ⇒ Pr. 73 "speed setting signal" (Refer to page 125.)

4.25 Power failure stop functions (Pr. 261 to Pr. 266)

4.25.1 Power-failure deceleration stop function (Pr. 261 to Pr. 266
When a power failure or undervoltage occurs, the inverter can be decelerated to a stop.
Remove the jumpers from across terminals R-R1 and S-S1, and connect terminal R1 to terminal P and
terminal S1 to terminal N.
Parameter
Name
Power failure stop
261
selection
Subtracted speed at
262
deceleration start
Subtraction starting
263
speed
Power-failure
264
deceleration time 1
Power-failure
265
deceleration time 2
Power-failure
266
deceleration time
switchover speed
Power supply
Output speed
Switchover
speed
Pr.266
Setting
Minimum Setting
Range
Increments
to
%
0
200
to
%
0
200
200
150
Pr.252
100
Pr.253
50
0
0V
Voltage across terminals 2-5
Factory Setting
0
90r/min
1800r/min
5s
9999
1800r/min
Subtracted speed
Pr.264
Pr.262
Power-failure deceleration time 1
Time
169
Additional function 2 (Pr. 252, Pr. 253)
with
without
with
without
Encoder
Encoder
Encoder
Encoder
Speed
Torque
Factory Setting
%
%
0.1
50
%
%
0.1
150
Factory setting
(50% to 150%)
5V
10V
Encoder
Setting Range
0, 1
0 to 600r/min
0 to 3600r/min, 9999
0 to 3600/0 to 360s
0 to 3600/0 to 360s, 9999
0 to 3600r/min
Pr.265
Power-failure deceleration time 2
)
Remarks
Extended mode
with
without
with
without
Encoder
Encoder
Encoder
)
Speed
Torque
Remarks
Extended mode
4

Advertisement

Table of Contents

   Related Manuals for Mitsubishi Electric FR-V560

   Related Content for Mitsubishi Electric FR-V560

Comments to this Manuals

Symbols: 0