Mitsubishi Electric FR-V560 Instruction Manual page 48

Vector inverter
Table of Contents

Advertisement

Setting
Signal
Positive
Negative
Name
logic
logic
Regenerative status
32
132
Y32
output
33
133
RY2
Operation ready 2
34
134
LS
Low speed output
35
135
TU
Torque detection
36
136
Y36
In-position
Maintenance timer
37
137
MT
output
Start time tuning
39
139
Y39
completion
40
140
Y40
Trace status
41
141
FB
Speed detection
Second speed
42
142
FB2
detection
Third speed
43
143
FB3
detection
44
144
RUN2
Inverter running 2
96
196
REM
Remote output
97
197
ER
Minor fault output 2
98
198
LF
Minor fault output
99
199
ABC
Alarm output
9999
——
No function
0 to 99: Positive logic, 100 to 199: Negative logic
Function
For vector control
Output on completion of pre-excitation. Turned on at an output start when pre-
excitation is not made.
Output when the speed falls to or below any preset low speed.
Output when the motor torque rises above the predetermined value (Pr.864).
(Refer to page 194.)
Acts as an in-position signal.
Refer to Pr. 890 to Pr. 892 (maintenance output function) (page 199).
Output on completion of start time tuning
Acts as a trace completion signal.
Output when the motor output speed (feed back value) exceeds the preset
speed.
Perform in the same way as FU, FU2 and FU3 under V/F control.
• Output during forward operation or the reverse signal is ON.
• Output at deceleration even during forward rotation or the reverse signal is
OFF. (Does not output during pre-excitation LX is ON.)
• Output during the orientation command signal (X22) is ON.
• Switched ON when the servo is ON (LX-ON) under position cotrol. (Switched
OFF when the servo is OFF. (LX-OFF)
Refer to Pr. 495 to Pr.497 (page 181).
At occurrence of a major fault, the base circuit is shut off immediately. At
occurrence of a minor fault, the base circuit is shut off after deceleration to a
stop.
Output when a minor fault (fan fault or communication error alarm) occurs.
Output when the inverter's protective function is activated to stop the output (major
fault).
39
How to use the output signals (assigned terminals
DO1 to DO3, ABC) (Pr. 190 to Pr. 192, Pr. 195)
Operation