Mitsubishi Electric FR-V560 Instruction Manual page 158

Vector inverter
Table of Contents

Advertisement

Instruction
No.
Item
Code
Alarm definition
3
HF4
all clear
4
Run command
HFA
Inverter status
5
H7A
monitor
Set speed
write
HEE
2
(E
PROM)
6
Set speed
HED
write (RAM)
Set speed
2
H6E
(E
PROM)
7
read
Set speed
H6D
(RAM) read
8
Inverter reset
HFD
Parameter all
9
HFC
clear
Parameter
10
H80 to HFD
write
Parameter
11
H00 to H7B
read
H7F
12
HFF
Communication functions (Pr. 117 to Pr. 124)
H9696: Clears the error history.
b7
b0
0
0
0
0
0
0
1
0
(For example 1)
[Example 1] H02
Forward rotation
[Example 2] H00
Stop
b7
b0
0
0
0
0
0
0
1
0
(For example 1)
[Example 1] H02
During forward
······
rotation
Stop due to
[Example 2] H80
······
alarm occurrence
* Output data varies with the settings of Pr. 190 to Pr. 192 and Pr. 195.
HFF=0
H0000 to H1C20: 1r/min increments (hexadecimal) (4 digits)
HFF=1
H0000 to H11940: 0.1r/min increments (hexadecimal) (6 digits)
To change the running speed consecutively, write data to
the inverter RAM.
(Instruction code: HED)
HFF = 0
H0000 to H1C20: 1r/min increments (hexadecimal) (4 digits)
HFF = 1
H0000 to 11940: 0.1r/min increments (hexadecimal) (6 digits)
H9696: Resets the inverter.
As the inverter is reset at start of communication by the computer,
the inverter cannot send reply data back to the computer.
All parameters return to the factory settings.
Any of four different clear operations is performed according to the data.
Pr.
Communication
Pr.
Data
H9696
H9966
×
H5A5A
×
H55AA
When parameter all clear is executed for H9696 or H9966, communication-
related parameter settings also return to the factory settings. When
resuming operation, set the parameters again.
*Pr. 75 is not cleared.
Refer to the data list (page 226) and write and/or read parameter values as
required.
Parameter description is changed according to H00 to H09 setting. Refer to
the parameter data code list (page 226) for details of the setting value.
CAUTION
When the instruction code "HFF" was rewritten, increments
of the speed monitor, write and read is changed.
HFF = "0" . . . . . . . . . . . . .1r/min increments
HFF = "1" . . . . . . . . . . . . .0.1r/min increments
HFF = more than "2" . . . .1r/min increments
149
Description
b0:
b1: Forward rotation (STF)
b2: Reverse rotation (STR)
b3:
b4:
b5:
b6:
b7:
b0: Inverter running (RUN)
b1: Forward rotation
b2: Reverse rotation
b3: DO1*
b4: DO2*
b5: DO3*
b6: Speed detection (FB)
b7: Alarm occurrence*
Calibration
Other Pr. *
Pr.
×
×
Number
of Data
Digits
4 digits
2 digits
2 digits
4 digits
(6 digits)
4 digits
(6 digits)
4 digits
HEC
HF3
HFF
4 digits
4 digits
2 digits
4

Advertisement

Table of Contents
loading

Table of Contents