Mitsubishi Electric FR-V560 Instruction Manual page 113

Vector inverter
Table of Contents

Advertisement

Operation selection functions 1 (Pr. 17 to Pr. 37)
Pr. 29 = 4 (S-pattern acceleration/deceleration C)
The S-pattern acceleration/deceleration C switch signal (X20) changes an acceleration/deceleration curve.
Pr.380
Pr.380
Set speed
OFF
S-pattern C switch
(X20)
X20 Signal
As the acceleration/deceleration time during acceleration/deceleration, set the percentage to the acceleration/
deceleration time T in Pr. 380 to Pr. 383.
Parameter setting (%) = Ts / T ×100%
REMARKS
• At a start, the motor starts at Pr. 13 "starting speed" when the start signal turns on.
• If there is a difference between the speed command and speed at a start of deceleration due to torque restriction operation
etc., the speed command is matched with the speed to make deceleration.
Related parameters
• Base frequency setting (acceleration/deceleration time setting) ⇒ Pr. 3 "base frequency" (Refer to page 90.)
• X20 signal setting when Pr. 29 = 4 (S-pattern acceleration/deceleration switch) ⇒ Pr. 180 to Pr. 187 (input terminal function
selection) (Refer to page 163.)
• Starting speed setting ⇒ Pr. 13 "starting speed" (Refer to page 97.)
• Pr. 20 "acceleration/deceleration reference speed" ⇒ Refer to page 91.
Pr.381
Pr.382
Pr.382
Pr.381
Pr.383
ON
ON
OFF
Operation
Pr. 380 "acceleration S
OFF
pattern 1"
Pr. 382 "acceleration S
ON
pattern 2"
S-pattern acceleration
Ts
T
CAUTION
Change the S pattern acceleration/
deceleration C switch (X20) after the speed
becomes constant. S pattern operation
before switching continues even if the X20 is
changed during acceleration or
Pr.383
deceleration.
During Acceleration
During Deceleration
Pr. 381 "deceleration
S pattern 1"
Pr. 383 "deceleration
S pattern 2"
Linear acceleration
Ts
104

Advertisement

Table of Contents
loading