Download  Print this page

Mitsubishi Electric FR-V560 Instruction Manual Page 89

Vector inverter.
Hide thumbs

Advertisement

Parameter lists
Parameter
Function
No.
110
Third acceleration/deceleration time
Third functions
111
Third deceleration time
Output terminal
116
Third speed detection
function
117
Communication station number
118
Communication speed
119
Stop bit length/data length
120
Parity check presence/absence
Communication
functions
121
Number of communication retries
122
Communication check time interval
123
Waiting time setting
124
CR, LF presence/absence selection
128
PID action selection
129
PID proportional band
130
PID integral time
PID control
131
Upper limit
132
Lower limit
133
PID action set point for PU operation
134
PID differential time
140
Backlash acceleration stopping speed
141
Backlash acceleration stopping time
Backlash
142
Backlash deceleration stopping speed
143
Backlash deceleration stopping time
144
Speed setting switchover
Display
functions
145
Parameter for the option (FR-PU04V).
150
Output current detection level
151
Output current detection period
Current
detection
152
Zero current detection level
153
Zero current detection period
156
Stall prevention operation selection
Sub functions
157
OL signal output timer
158
DA2 terminal function selection
Display
functions
160
Extended function selection
Automatic restart after instantaneous
162
power failure selection
Automatic
restart after
163
First cushion time for restart
instantaneous
164
First cushion voltage for restart
power failure
165
Restart current restriction level
168
Maintenance
Maker setting parameters. Do not make setting.
functions
169
171
Actual operation hour meter clear
Initial monitor
180
DI1 terminal function selection
181
DI2 terminal function selection
182
DI3 terminal function selection
183
DI4 terminal function selection
187
STR terminal function selection
Terminal
assignment
190
DO1 terminal function selection
functions
191
DO2 terminal function selection
192
DO3 terminal function selection
195
ABC terminal function selection
232
Multi-speed setting (speed 8)
Multi-speed
operation
233
Multi-speed setting (speed 9)
Name
Setting Range
0 to 3600/0 to
360s
0 to 3600/0 to
360s, 9999
0 to 3600r/min
0 to 31
48, 96, 192
0, 1, 10, 11
0, 1, 2
0 to 10, 9999
0 to 999.8s, 9999
0 to 150ms, 9999
0, 1, 2
10, 11, 30, 31
0.1 to 1000%,
9999
0.1 to 3600s,
9999
0 to 100%, 9999
0 to 100%, 9999
0 to 100%
0.01 to 10s, 9999
0 to 3600r/min
0 to 360s
0 to 3600r/min
0 to 360s
0, 2, 4, 6, 8, 10
0 to 200%
0 to 10s
0 to 200.0%
0 to 1s
0 to 31, 100, 101
0 to 25s, 9999
1 to 3, 5 to 12, 17,
18, 21,
32 to 34, 36
0, 1
0, 1, 10
0 to 20s
0 to 100%
0 to 200%
0
0 to 3, 5, 8 to 12,
14 to 16, 20, 22 to
28, 42 to 44,
9999
0 to 8, 10 to 16,
20, 25 to 27, 30 to
37, 39, 40 to 44,
96 to 99, 100 to
108, 110 to 116,
120,125 to 127,
130 to 137, 139,
140 to 144, 196 to
199, 9999
0 to 3600r/min,
9999
0 to 3600r/min,
9999
80
Minimum
Refer
Setting
Factory Setting
Increments
0.1s/0.01s
5s
0.1s/0.01s
9999
1r/min
1800r/min
1
0
1
192
1
1
1
2
1
1
0.1s
9999
1ms
9999
1
1
1
10
0.1%
100%
0.1s
1s
0.1%
9999
0.1%
9999
0.01%
0%
0.01s
9999
1r/min
30r/min
0.1s
0.5s
1r/min
30r/min
0.1s
0.5s
1
0
0.1%
150%
0.1s
0
0.1%
5.0%
0.01s
0.5s
1
1
0.1s
0
1
1
1
0
1
0
0.1s
0s
0.1%
0%
0.1%
150%
1
0
1
0
1
1
1
2
1
3
1
9999
1
0
1
1
1
2
1
99
1r/min
9999
1r/min
9999
Custo
mer
To
Setting
91
91
108
141
141
141
141
141
141
141
141
152
152
152
152
152
152
152
102
102
102
102
106
159
159
160
160
161
162
110
163
114
114
114
114
163
163
165
90
90

Advertisement

Table of Contents

   Related Manuals for Mitsubishi Electric FR-V560

Comments to this Manuals

Symbols: 0
Latest comments: