Parameter
Function
No.
29
Acceleration/deceleration pattern
30
Regenerative function selection
31
Speed jump 1A
32
Speed jump 1B
Operation
33
Speed jump 2A
selection
functions
34
Speed jump 2B
35
Speed jump 3A
36
Speed jump 3B
37
Speed display
41
Up-to-speed sensitivity
Output terminal
42
Speed detection
functions
43
Speed detection for reverse rotation
44
Second acceleration/deceleration time
Second
functions
45
Second deceleration time
Output terminal
50
Second speed detection
function
52
DU/PU main display data selection
53
PU level display data selection
Display
functions
54
DA1 terminal function selection
55
Speed monitoring reference
56
Current monitoring reference
57
Restart coasting time
Automatic
restart
58
Restart cushion time
Additional
59
Remote setting function selection
function
60
Intelligent mode selection
65
Retry selection
67
Number of retries at alarm occurrence
68
Retry waiting time
69
Retry count display erasure
70
Special regenerative brake duty
Operation
selection
71
Applied motor
functions
72
PWM frequency selection
73
Speed setting signal
Reset selection/disconnected PU
75
detection/PU stop selection
77
Parameter write disable selection
78
Reverse rotation prevention selection
79
Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor excitation current (no load current) *
83
Rated motor voltage
84
Rated motor frequency
Motor
constants
90
Motor constant R1 *
91
Motor constant R2 *
92
Motor constant L1 *
93
Motor constant L2 *
94
Motor constant X *
95
Online auto tuning selection
Motor
constants
96
Auto tuning setting/status
Name
Setting Range
0, 1, 2, 3, 4
0, 1, 2
0 to 3600r/min,
9999
0 to 3600r/min,
9999
0 to 3600r/min,
9999
0 to 3600r/min,
9999
0 to 3600r/min,
9999
0 to 3600r/min,
9999
0, 1 to 9998
0 to 100%
0 to 3600r/min
0 to 3600r/min,
9999
0 to 3600s/0 to
360s
0 to 3600s/0 to
360s, 9999
0 to 3600r/min
0, 5 to 12, 17 to
20, 23, 24,
32 to 35, 38, 100
0 to 3, 5 to 12, 17,
18
1 to 3, 5 to 12, 17,
18, 21,
32 to 34, 36
0 to 3600r/min
0 to 500A
0, 0.1 to 5s, 9999
0 to 60s
0, 1, 2, 3
0, 7, 8
0 to 5
0 to 10, 101 to
110
0 to 10s
0
0 to 15%/0 to
30%/0%
0, 3 to 8, 10, 13 to
18, 30, 33, 34
1 to 6
0, 4, 10, 14
0 to 3, 14 to 17
0, 1, 2
0, 1, 2
0 to 4, 6 to 8
0.4 to 55kW
2, 4, 6
0 to , 9999
0 to 1000V
20 to 200Hz
0 to , 9999
0 to , 9999
0 to , 9999
0 to , 9999
0 to , 9999
0, 1, 2
0, 1, 101
79
Parameter lists
Minimum
Refer
Setting
Factory Setting
Increments
1
0
1
0
1r/min
9999
1r/min
9999
1r/min
9999
1r/min
9999
1r/min
9999
1r/min
9999
1
0
0.1%
10%
1r/min
300r/min
1r/min
9999
0.1s/0.01s
5s
0.1s/0.01s
9999
1r/min
750r/min
1
0
1
1
1
1
1r/min
1800r/min
Inverter rated
0.01A
output current
0.1s
9999
0.1s
1.0s
1
0
1
0
1
0
1
0
0.1s
1s
1
0
0.1%
0%
1
30
1
1
1
0
1
14
1
0
1
0
1
0
0.01kW
Inverter capacity
1
4
9999
0.1V
575V
0.01Hz
60Hz
9999
9999
9999
9999
9999
1
0
1
0
Custo
mer
To
Setting
102
105
106
106
106
106
106
106
106
108
108
108
101
101
108
110
110
110
113
113
114
114
116
118
121
121
121
121
105
123
124
125
127
128
129
129
4
132
132
136
132
132
136
136
136
136
136
139
132

Advertisement