Model specifications

6.1 Model specifications
575V class
Type FR-V560-[][]K-NA
Applied motor capacity (kW (HP))
Rated capacity (kVA) (Caution 1)
Rated current (A)
Overload current rating (Caution 2)
Voltage (Caution 3)
Regenerative
braking torque
(Caution 7)
Rated input AC voltage, frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply capacity (kVA)
(Caution 5)
Protective structure (JEM 1030)
Cooling system
Approx. weight (kg (Ibs))
CAUTION
1. The rated output capacity indicated assumes that the output voltage is 575V.
2. The overload current rating indicated in % is the ratio of the overload current to the rated output
current of the inverter. For repeated duty, allow time for the inverter and motor to return to or below
the temperatures under 100% load.
3. The maximum output voltage does not exceed the power supply voltage. The maximum output
voltage can be changed within the setting range. However, the PWM pulse voltage value of the
inverter output side voltage remains unchanged at about
4. The short-time rating is 5s.
5. The power supply capacity varies with the value of the power supply side inverter impedance
(including those of the input reactor and cables).
6. Open type (IP00) when the plug-in option is fitted after removal of the option wiring port cover.
7. For the 2.2K to 15K capacities, using the high-duty brake resistor will achieve the performance of
100% torque/10%ED.
8. If the motor is one rank lower in capacity than the inverter, it can be used by setting Pr. 80 "motor
capacity" and Pr. 81 "number of motor poles". Other manufacturers' motors and special motors can
be used by performing online auto tuning.
2.2
2.2
(3)
Max. value
Permissible duty
5.5
6.0
(13.2)
3.7
7.5
3.7
7.5
(5)
(10)
4
6.1
12
4
6.1
12
150% 60s, 200% 0.5s (inverse-time characteristics)
Three-phase, 575V 60Hz
100% 5s
2%ED
Three-phase, 575V 60Hz
490 to 632V 60Hz
9
17
Enclosed type (IP20 NEMA1) (Caution 6)
Forced air cooling
6.0
6.0
(13.2)
(13.2)
2
that of the power supply.
220
15
22
37
15
22
37
(20)
(30)
(50)
22
33
55
22
33
55
20%
Continuous
±5%
28
41
66
14.0
14.0
35.0
(30.9)
(30.9)
(77.0)
55
55
(75)
84
84
100
35.0
(77.0)