Running Manual Calibrate - Printronix T5204R Administrator's Manual

Sl/t5r energy saver rfid smart label and thermal printers
Hide thumbs Also See for T5204R:
Table of Contents

Advertisement

Chapter
2
Printing Adjustments
Media Sensor
Position
1023
0767
0511
Paper Out(301)
0255
Gap(160)
0000
Indicates Type of Gap/Mark
Sensing Selected

Running Manual Calibrate

Manual Calibrate should be performed only when the values derived from
Auto Calibrate fail to improve the media sensors' ability to sense label length
indicators on the installed media. You must first enable "Admin User" in the
PRINTER CONTROL menu before accessing or initializing Manual Calibrate
in the CALIBRATE CTRL menu.
NOTE: Verify the Gap/Mark Sensor option (Gap, Mark, Advanced Gap,
1. Press
2. Press the ↓ and
displays.
3. Press
4. Press ↑ until "Admin User" displays, then press
66
Detected Amplitude
of the Antenna
Advanced Notch, or Disable) matches the installed media. See
"Sensing Different Media Types" on page 59.
Ensure the media sensors are horizontally positioned to permit
sensing of the label length indicators. See "Positioning the Media
Sensors" on page 54.
Ensure the Print Mode option selected in the QUICK SETUP menu
matches the media installed. Select "Direct" for heat sensitive media
(no ribbon required) or "Transfer" for thermal transfer media (ribbon
required).
If you try to do a Manual Calibrate when Peel-Off Media Handling is
enabled, the LCD will display, "CANNOT CALIBRATE/Disable Peel-
Off." Before you can do a Manual Calibrate, you must select another
media handling mode.
. .
to place the printer in Menu mode.
.
keys together until "ENTER SWITCH UNLOCKED"
. .
until "PRINTER CONTROL" displays.
.
FEED
Detected Amplitude
of the Gap
+
until "Enable" displays.