Diagnostics for E0xx, Bad NVM, or ILL NVM Errors
Table 18. LCD Message Troubleshooting (continued)
Displayed Message
OPTION NOT
INSTALLED
OVERALL GRADE
FAIL
324
Can User
Explanation
Correct?
Yes
If the printer is
powered on with the
cutter enabled in the
Media Handling menu,
but the cutter itself is
open (in the down
position, or the cutter
upper enclosure is
removed) the printer
cannot detect the
cutter. When using the
cutter, the printer must
be powered on with the
cutter in the up position
and the cutter upper
enclosure installed.
Yes
Overall data validation
failure: decodeability,
percent decode,
defects, modulation,
EC Min, Rmin, and/or
symbol contrast.
Solution
1. Check that the cutter
option is installed,
connected in the up
position and the upper
enclosure installed before
powering on the printer.
2. Install the cutter option or
change to the correct
Media Handling option in
the QUICK SETUP menu.
3. If the error persists,
contact your authorized
customer service
representative.
1. Press Pause to clear the
message.
2. Adjust the parameter that
is causing the failure. Run
a Scan Report to see
which parameter failed.
3. Lower the Overall Grade to
a point where the worst
parameter grade will be
above the Overall Grade
threshold.