CONTROl PANel PACKING lIST
1 D8XD or D16XD Main board
1 Housing
1 Keypad (not supplied with all models)
1 Power supply (Australia only)
1 12V 7Ah battery (optional)
1 Dialler telephone lead
1 User manual
1 Installer manual
9 or 17 end Of line resistors 2.2k (D8x/D16x)
1 lead assembly for battery
1 lead assembly for internal tamper
2 Housing cover screws
4 Circuit board standoffs
92
sPeCiFiCAtions
Plastic housing dimensions ... 235w x 300h x 90d mm.
Power requirement ................ 17VAC or 20VDC
Quiescent current draw ......... 80mA with 1 keypad.
Rechargeable battery............. 12 volt 7.0 Amp/hour Sealed lead Acid.
Battery charging current ........ 350mA maximum, current limited.
Dynamic battery test .............. Backup battery is tested under load, hourly and on arming.
Fuses ...................................... 2 Amp auto resetting / Siren output & Reset output.
INPUTS / OUTPUTS
Zones ..................................... 8 or 16 zone inputs. 2 x 24hr tamper inputs.
end of line resistor ................. Default 2200 Ohms (2.2k). Other values programmable.
Maximum keypads ................. 3.
lISTeN header ....................... Output for audio alerts and dialler listen-in.
ReCeIVeR header.................. Connection for the Ness Radio Interface.
AUX header ............................ Multi-pin connector provides outputs Aux1, Aux2, Aux3, Aux4, 12V DC
SeRIAl header ....................... Serial data port for data input.output and direct connect programming
ReADeR header ..................... Multi-pin port for connecting up to 3 Ness proximity access card readers.
Siren ....................................... On board siren driver with timed output .
Strobe ..................................... 12V DC timed output. Maximum 2 x 1 Watt strobe lights.
Reset ...................................... 12V DC timed output. Maximum 3 x 12V piezo screamers.
equipment power output ....... 13.8V DC output for powering detectors and other equipment. Maximum
APProVAls
emC ComPliAnCe
eN 50130-4:1996 Part 4: electromagnetic compatability. electrostatic Discharge, Radiated RF
Immunity, electrical Fast Transient/burst. Surge Immunity, Conducted RF Immunity, Voltage Dips and
Interruptions, Mains Supply Variations.
AS/NZ CISPR 22:2002- Class B, electromagnetic Radiation, Terminal Disturbance Voltage.
eN61000-6-3:2001, Harmonic Current emissions, Voltage fluctuations and Flicker.
teleCom
TBR21, eU. PTC200, NeW ZeAlAND TeleCOM . AS ACIF S002, AUSTRAlIA
sAFety
eN60950:2000 inc Country Deviations, Safety of Information Technology equipment
AS/NZ3260-1993 incl. AMDTS 1,2,3 &4. TS001-1997 ACA Australian Communications Authority
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
500mA auto resetting / 12 volt auxiliary outputs.
200 mA auto resetting / strobe output.
and connection for output expander/s.
using NessComms™ software.
Maximum 3 x 8 Ohm horn speakers.
500mA.