Output Expander Options - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

P r o g r A m m i n g
To D8/D16
AUX header
P117e 1e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No Output expander.
notes
• Connect up to two Output Expander
boards.
P117e 2e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF
notes
• The second expander plugs into
the second 6-way header on the first
expander. The expander closest to the
panel becomes expander 1.
• The User Code outputs will follow the
ON/OFF state of the User Codes 13 to 15.
These outputs can be made to change
via:
A) Radio key. Pressing the ON button
turns the output On, OFF turns it OFF.
A Radio key must be programmed to a
User Code 13~15 for this will operate.
B) Radio keypad auxiliary key. The
radio keypad auxiliary key (there are 2
auxiliary keys) must be programmed to
a User Code 13~15.
C) The D8x/D16x keypad using ARM
- DISARM with a User Code. enter
Arm+User_Code_13~15 to turn the
output on. User_Code_13~15 + e will
turn the output off.
Note that the USeR CODe does not
have to be assigned to an AReA for this
to work.
• If P117E 6E is ON then the ARM,
DISARM buttons on Radio Keys do not
change the Code13-15 outputs on the
output expander.
Only the AUX button works, pulsing ON
the Code13-15 output for the time set by
P145e.
54
Option No.
P117e
enAble oUtPUt exPAnDer
Selecting this option enables the optional 106-011 Output expander.
When this option is enabled, the AUX connector on the main board will only drive the
Output expander.
When this option is disabled, the AUX header is used for the 106-013 Four Relay
Board.
PROGRAMMING SeQUeNCe:
P117e 1e toggles the option ON and OFF
oFF: no output expander
on: output expander enabled
exPAnDer oUtPUt FormAt A, b, C
Use this option along with option P117e 5e to configure the output expander outputs
as per the output tables.
Three different combinations of outputs are available for either a single or dual output
expanders.
PROGRAMMING SeQUeNCe:
P117e 2e toggles the option ON and OFF
Output Format A
P117e 2e = OFF
P117e 5e = OFF
oUtPUt
exPAnDer 1
(Or if using only
one expander)
1
Zone 1
2
Zone 2
3
Zone 3
4
Zone 4
5
Zone 5
6
Zone 6
7
Zone 7
8
Zone 8
9
Zone 9
10
Zone 10
11
Zone 11
12
Zone 12
13
Zone 13
14
Zone 14
15
Zone 15
16
Zone 16
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Description
1e
enable Output expander
2e
expander Output Format A & B
3e
Day Zone follower
4e
Output exclude
5e
expander Output Format C
6e
User Code Toggle or Pulse
7e
[not used]
8e
[not used]
Output Format B
P117e 1e = ON
exPAnDer 2
exPAnDer 1
(Or if using only
one expander)
Aux 5
Zone 1
Aux 6
Zone 2
Aux 7
Zone 3
Aux 8
Zone 4
User Code 13
Zone 5
User Code 14
Zone 6
User Code 15
Zone 7
Tel. line Fail
Zone 8
Aux 1
Aux 1
Aux 2
Aux 2
Aux 3
Aux 3
Aux 4
Aux 4
Arm Home
Arm Home
Mains Fail
Mains Fail
Battery Fail
Battery Fail
ext. Tamper
ext. Tamper
Output Format C
P117e 1e = ON
P117e 2e = ON
P117e 5e = OFF
exPAnDer 2
exPAnDer 1
(Or if using only
one expander)
Aux 5
Aux 5
Aux 6
Aux 6
Aux 7
Aux 7
Aux 8
Aux 8
User Code 13
User Code 13
User Code 14
User Code 14
User Code 15
User Code 15
Tel. line Fail
Tel. line Fail
Zone 9
Aux 1
Zone 10
Aux 2
Zone 11
Aux 3
Zone 12
Aux 4
Zone 13
Arm Home
Zone 14
Mains Fail
Zone 15
Battery Fail
Zone 16
ext. Tamper
Default
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
P117e 1e = ON
P117e 2e = OFF
P117e 5e = ON
exPAnDer
2
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Zone 9
Zone 10
Zone 11
Zone 12
Zone 13
Zone 14
Zone 15
Zone 16

Hide quick links:

Advertisement

Table of Contents
loading