P r o g r A m m i n g
Only one of the P124e options may be selected.
Option No.
Description
P124e 1e
Zone Alarms to AUX4
2e
enable extension Sonalert
3e
enable AUX4 for AutoTimer
4e
Radio Key Panic Pulses AUX4
5e
enable AUX4 Fail To Communicate Output
6e
[not used]
7e
[not used]
8e
Reader output pulses AUX4
P124e 1e-8e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
1e on.
notes
Only one option can be on. Turning an
option on turns off another.
relAteD oPtions
P143e 1e-8e enhanced AUX4 options.
P374e 5e-6e AutoTimer1 AUX4 options.
P379e 5e-6e AutoTimer2 AUX4 options.
P384e 5e-6e AutoTimer3 AUX4 options.
P389e 5e-6e AutoTimer4 AUX4 options.
P124e 1e
relAteD oPtions
P59e Aux2 zones.
P122e 1e Zone Alarms to AUX2
P124e 2e
notes
The extension beeper can either be a
standard 12V sonalert or wire directly to the
Ness Quantum Sonic as shown. Keypad
beeps will be heard at low volume from the
Quantum Sonic's onboard siren. (Normal
siren sound is unaffected).
P124e 3e
Available in D8x/D16x V6 and later.
relAteD oPtions
P370e to P389e. AutoTimers.
P124e 4e
Available in D8x/D16x V8 and later.
relAteD oPtions
P148e AUX4 Timer
P124e 5e
Available in D8x/D16x V6 and later.
relAteD oPtions
P370e to P389e. AutoTimers.
P124e 8e
relAteD oPtions
P318e, P328e, P338e, P319e, P329e,
P339e.
64

AUx4 OUTPUT OPTIONS

Default
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
AUx4 oUtPUt oPtions
P124e is one of several options which control the behaviour of the AUX4 output.
One of the most powerful features of the D8x/D16x panels is the flexibility to control
the AUX outputs by various events and alarms. If the AUX4 output does not behave as
expected, please check all related options such as AutoTimers and P144e options.
TO PROGRAM
1. Press P124e.
2. Press 1e ... 8e to turn an option on. Only one option can be on.
Zone AlArms to AUx4
With this option ON, zones selected in P59e will turn on Aux4 when they go into alarm. The
Aux4 output turns off when the panel is disarmed/reset.
enAble extension sonAlert
enables the Aux4 output to duplicate all keypad beeps including keypress beeps. This is
useful in cases where, for example, entry beeps or other keypad beeps need to be heard in
more than one location on the premises. (Adding an additional keypad would also achieve
the same result).
enAble AUx4 For AUtotimer
When this option is on, AUX4 is enabled for use by AutoTimer.
rADio key PAniC PUlses AUx4
When this option is on, Radio Key/s Panic button will PUlSe the Aux4 output.
When this option is on, Radio Key Panic buttons will no longer sound alarms or report
alarms by dialler.
Note that P122e 4e (Radio Key Panic Pulses AUX2) over-rides this option.
enAble AUx4 FAil to CommUniCAte oUtPUt
When this option is enabled AUX4 will turn on at the start of the fourth dialout attempt.
This can be used as Fail To Communicate output to trigger backup communications
devices such as GSM. The AUX4 output is automatically turned off on the next successful
communication attempt or when the panel is next disarmed.
reADer oUtPUt to AUx4
This option enables an access control reader to pulse AUX4 when a valid access card is
presented. Set the reader using P318e, P328e or P338e.
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Any or all of the P144e options may be selected.
Option No.
Description
P144e 1e
Area1 Armed to AUX4
2e
Area2 Armed to AUX4
3e
Home Mode arm to AUX4
4e
Keypad toggle AUX4
5e
Telephone remote control of AUX4
6e
[not used]
7e
[not used]
8e
Pulse AUX4
Default
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF